Normally, the straw briquetting machine should first pays attention to the cleanliness and hygiene of the equipment, especially checking the automatic drain valve on the filter every day. Of course, in order to make the machine run better, special attention must be paid when replacing the tower and boosting the pressure. Before each use, it is necessary to check in advance.
Of course, it is necessary to regularly check the operating conditions, inlet pressure, inlet temperature, and air flow rate of the equipment.
Check whether the moisture indicator of the device is normal. Generally speaking, if the moisture indicator is blue, it indicates that the raw materials are too dry. If the moisture indicator is pink, it indicates that the raw materials are too wet.
Of course, it is also necessary to check if the muffler is blocked due to stains. If it is blocked, the equipment usually makes a lot of noise during operation. If the tower backwash pressure is too high again, we should replace the muffler in a timely manner.
Before starting the straw briquetting machine, we should first use our hands to rotate the pressing wheel and check whether it operates flexibly and normally, whether there is any collision between the pressing wheel and the mold, whether the direction of rotor rotation is correct, and whether the lubrication of the lubricating parts of the briquetting machine is good.
After starting the straw briquetting machine, it should idle for 1-2 minutes and then start feeding and working if there is no other abnormal phenomena. When feeding raw materials to the straw briquetting machine, it should be evenly and orderly. If there is noise, the temperature of the bearing or engine body is too high, or the material is sprayed outward, we should stop the machine immediately, and check the machine to troubleshoot the problem step by step.
Stop feeding materials before the straw briquetting machine stops. Cut off its power after all the materials in the machine are discharged. Clean and maintenance the machine after shutdown. When the belt is shut down for a long time, the belt should be loosened to prevent it from being too tight to be damaged.